| GENERAL PROPERTIES
Harbor Bosun Yellow/Green products are specially formulated versions of Xanthene dye, certified by NSF International to ANSI/NSF Standard 60 for use in drinking water. It may be detected visually, by UV light and by appropriate fluoremetric equipment. Today it is most often used visually. This dye has been used by the military to mark downed pilots for search and rescue operations over large water bodies. Visually the dye appears yellow/green, depending on its concentration and under UV light as lime green.
Harbor Bosun is resistant to absorption on most suspended matter in fresh and salt water. Based on biochemical oxygen demand (BOD) studies, the dye is biodegradable with 65% of the available oxygen consumed in 7 days. Harbor Bosun is also sensitive to sunlight and subsequent degradation. Print the General Properties Page
|
General Properties
|
Tablets
|
Liquids
|
|
Detectability of active ingredient (1)
|
Visual <100ppb
|
Visual <100ppb
|
|
Maximum Absorbance Wavelength (2)
|
490/520 nm
|
490/520 nm
|
|
Appearance
|
Orange Convex
1.6cm diameter
|
Reddish, brown
aqueous solution
|
|
NSF (Max use of level in potable water)
|
6.0ppb
|
10.0ppb
|
|
Weight
|
1.35 gms ± 0.05
|
|
|
Dissolution Time (3)
|
50% <3 minutes
95% <6 minutes
|
Immediate
|
|
Specific Gravity
|
|
1.05 ± 0.05 @ 25 C
|
|
Viscosity (4)
|
|
1.8 cps
|
|
pH
|
|
8.5 ± 0.5 @ 25 C
|
|
| Coverage of Products |
Tablets |
Liquids |
| Visual |
3-4 / 60 gallons |
1 oz. - 2500 gallons |
Caution: These products may cause irritation and/or staining if allowed to come in contact wit the skin. The use of gloves and goggles is recommended when handling this product, as with any other dye or chemical.
To our best knowledge the information and recommendations contained herein are accurate and reliable. However, this information and our recommendations are furnished without warranty, representation, inducement, or license of any kind, including, but not limited to the implied warranties and fitness for a particular use or purpose. Customers are encouraged to conduct their own tests and to read the material safety data sheet carefully before using.
1 In deionized water in 100 ml flask. Actual detectability and coverage in the field will vary with specific water conditions.
2 No significant change in fluorescence between 6 and 11 pH.
3 (One tablet, 1 gram of powder), in flowing deionized water in a 10 gallon tank.
4 Measured on a Brookfield viscometer, Model LV, UL adapter, 60 rpm @ 25&Mac176; C.